Nortel DMS-100 Series Replacement Procedures page 1003

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

13
Remove the NTMX72 card as shown in the following figures.
a
Locate the card to be removed on the appropriate shelf.
b
Open the locking levers on the card to be replaced and gently pull the
card toward you until it clears the shelf.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC-S (DS-1) Model A RCC2
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the left side of the
FSP. This protects the equipment against damage caused by
static electricity.
DANGER
Equipment damage
Take the following precautions when removing or inserting a
card:
1. Do not apply direct pressure to the components.
2. Do not force the cards into the slots.
1-971
NTMX72
(continued)