Hold the front cover of the line drawer to steady it using your left hand.
e
Pull the extractor away from the drawer, and the card will become
unplugged from its socket on the drawer backplane.
f
Continue pulling the card with the extractor until the card is clear of the
shroud.
g
Insert the card removed into the ESD container and store using local
procedures.
15
Replace the faulty card using the following substeps:
a
Remove the replacement card from the ESD container.
b
Slide the card in the shroud guide slots toward the drawer backplane.
c
Hold the front cover of the line drawer with your left hand to steady it.
d
Grasp the top and bottom edges of the card with the fingers of your right
hand.
e
Push the card toward the backplane until it plugs fully into the backplane
socket.
16
Close the line drawer.
At the MAP terminal
17
To perform a diagnostic test on the line, type
>DIAG
and press the Enter key.
Example of a MAP response:
ECOME004AH ***+LINE100 DEC17 10:04:26 0200 PASS LN_DIAG
LEN
HOST
DIAGNOSTIC RESULT Card Diagnostic
ACTION REQUIRED None
CARD TYPE EX17BA
If the DIAG command
passed
failed
18
To return the line to service, type
>RTS
and press the Enter key.
If RTS command
passed
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
01 0 11 02
NO DIRN
in an RSC LCM
OK
Do
step 18
step 19
Do
step 20
1-751
NTEX17
(continued)