Nortel DMS-100 Series Replacement Procedures page 790

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-758 XPM card replacement procedures (continued)
NTEX17
in an RSC-S (DS-1) Model A LCME
At the shelf
11
12
297-8021-547 Standard 14.02 May 2001
DANGER
Static electricity damage
Wear a wrist strap that connects to a wrist-strap grounding
point to handle circuit cards. The wrist-strap grounding point
is on a frame supervisory panel (FSP) or a modular
supervisory panel (MSP). The wrist strap protects the cards
against static electricity damage.
DANGER
Risk of equipment damage
Take these precautions when removing or inserting a card:
1. Do not apply direct pressure to the components.
2. Do not force the card into its slot.
DANGER
Risk of equipment damage
Proceed only if a step in a maintenance procedure directs you
here. If you perform this procedure without permission,
equipment damage can occur.
DANGER
Risk of electrocution
Proceed only if a step in a maintenance procedure directs you
here. If you perform this procedure without permission,
personal injury can occur.
Put on a wriststrap.
Note 1: A card shroud is required to insert or remove an NTEX17 card in
line drawers. This is a 6-inch (152 mm) card, and requires the card shroud
with apparatus code QTH58A and common product code A0313317.
Note 2: A card removal tool is required to remove the NTEX17 card from
line drawers. The apparatus code for the grip tool is QTH57A, and the
common product code is A0298292. You can also use the large grip tool
ITA9953.
Use the information you obtained in step 6 to locate the physical location of
the line card.
(continued)

Advertisement

Table of Contents
loading

Table of Contents