Nortel DMS-100 Series Replacement Procedures page 731

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NTBX72 card in an RSCE LCME
At your Current Location
1
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
2
Obtain an NTBX72 replacement card. Ensure the replacement card has the
same product equipment code (PEC), including suffix, as the card that is to
be removed.
At the MAP terminal
3
Set the MAP display to the PM level and post the LCME by typing
>MAPCI;MTC;PM;POST LCME site frame_no unit_no
and pressing the Enter key.
where
site
is the name of the site at which the LCME is located
frame_no
is the number of the frame in which the LCME is located
unit_no
is the number of the LCME with the faulty card
Example of a MAP display:
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC LCME
1-699
NTBX72
(continued)