Nortel DMS-100 Series Replacement Procedures page 162

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-130 XPM card replacement procedures (continued)
NT6X92
in an SMA2
(continued)
At the frame or cabinet
14
15
At the MAP terminal
16
17
297-8021-547 Standard 14.02 May 2001
WARNING
Static electricity damage
Wear a strap connected to the wrist strap grounding modular
supervisory panel (MSP) while handling cards. This strap
protects the cards against damage caused by static electricity.
Perform the common replacing a card procedure in this document.
Use the following information to determine the next step.
If you were directed here from
alarm clearing procedures
other
Load the inactive SMA2 unit by typing
>LOADPM UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the busied SMA2 unit
If load
passed
failed
Return the inactive SMA2 unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the SMA2 unit loaded in step 17
If RTS
passed
Do
step 18
step 16
Do
step 17
step 21
Do
step 18