Nortel DMS-100 Series Replacement Procedures page 147

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

SMA
PM
SMA
SMA 0 ISTb
Unit0:
Unit1:
6
Observe the MAP display and determine if the faulty card is in the active or
the inactive unit.
If the faulty card is in the
active unit
inactive unit
7
Switch the activity of the units by typing
>SWACT
and pressing the Enter key.
A confirmation prompt for the SWACT command is displayed at the MAP
terminal.
If SWACT
can continue at this time
cannot continue at this time
8
Confirm the system prompt by typing
>YES
and pressing the Enter key.
The system runs a pre-SWACT audit to determine the ability of the inactive
unit to accept activity reliably.
Note: A maintenance flag appears when maintenance tasks are in
progress. Wait until the flag disappears before proceeding with the next
maintenance action.
If the message is
SWACT passed
SWACT failed
Reason: XPM SWACTback
SWACT refused by SWACT
Controller
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
SysB
ManB
Offl
3
0
1
0
0
0
Links_OOS:
CSide 0, PSide 0
Act
InSv
Inact SysB
in an SMA
CBsy
ISTb
InSv
0
2
13
0
1
7
Do
step 7
step 10
Do
step 8
step 21
Do
step 10
step 9
step 9
1-115
NT6X92
(continued)