Nortel DMS-100 Series Replacement Procedures page 907

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

tape_no
is the number of the tape drive containing the PM load files
16
Go to step 27.
17
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
18
Access the disk utility level of the MAP display by typing
>DSKUT
and pressing the Enter key.
19
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 17
20
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
21
Go to step 27.
22
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
23
Access the disk utility level of the MAP display by typing
>DISKUT
and pressing the Enter key.
24
List all SLM disk volumes into your user directory by typing
>LV CM
and pressing the Enter key.
25
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 22
26
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an IOPAC HIE
1-875
NTMX45
(continued)

Advertisement