Nortel DMS-100 Series Replacement Procedures page 807

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NTEX17 in a STAR
At your current location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for checking
or accepting cards, or were directed to this procedure by your maintenance
support group.
2
Get a replacement card. Make sure that the replacement card and the card
that you remove have the same product engineering code (PEC) and PEC
suffix.
At the xEMS workstation
3
Go to the submap of the STAR line drawer with the NTEX17 card to be
replaced.
4
Place the cursor on the XLC you want to busy and use the mouse to select
Maintenance : XLC -> MB
and press the Enter key.
At the MAP terminal
5
To access the LTP level of the MAP display, type
>MAPCI;MTC;LNS;LTP
and press the Enter key.
Example of a MAP display:
POST
LCC PTY RNG .....LEN..........
Note: If you worked at the LTP level of the MAP display, a posted line can
be present. A posted line does not interfere with this maintenance
procedure.
6
To post the line for the card to be replaced, type
>POST
L
and press the Enter key.
where
site
is the PM location (alphanumeric)
frame_no
is the frame number (0 to 511)
unit_no
is the PM unit number (0 or 1)
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
DELQ
BUSYQ
site
frame_no
in a STAR
PREFIX
DN
STA F S LTA
unit_no
drawer_no
1-775
NTEX17
(continued)
TE
RESULT
slot_no

Advertisement

Table of Contents
loading

Table of Contents