1-276 XPM card replacement procedures (continued)
NT8X18
in an SMS-R
(continued)
At the frame
14
15
297-8021-547 Standard 14.02 May 2001
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the left side of the
frame supervisory panel of the SMS-R. This protects the
equipment against damage caused by static electricity. Do
not replace more than one 8X18 card at a time.
DANGER
Equipment damage
Take the following precautions when removing or inserting a
card:
1. Do not apply direct pressure to the components.
2. Do not force the cards into the slots.
Put on a wrist strap.
Remove the NT8X18 card as shown in the following figures.
a
Locate the card to be removed on the appropriate shelf.
b
Open the locking levers on the card to be replaced and gently pull the
card toward you until it clears the shelf.