Nortel DMS-100 Series Replacement Procedures page 808

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-776 XPM card replacement procedures (continued)
NTEX17
in a STAR
(continued)
LCC PTY RNG .....LEN..........
1FR
7
8
9
LCC PTY RNG .....LEN..........
1FR
297-8021-547 Standard 14.02 May 2001
drawer_no
is the line drawer number (0 to 19)
ckt_no
is the card slot number (0 to 31)
Example of a MAP display:
REM1 01 0 01 01
Determine the state of the posted line.
If the state of the line
is CPB, CPD
is CUT, HAZ, IDL, LO, PLO, SB step 9
is MB
is NEQ
is DEL, DMB, INB, LMB
Wait until the line state changes. Go to step 7.
To manually busy the line circuit, type
>BSY
and press the Enter key.
Example of a MAP display:
REM1 01 0 01 01
Note: Observe that the state that appears under the STA header changed
to MB.
If BSY command
passes
fails
DN
STA F S LTA
621 1134 IDL
Do
step 8
step 10
To determine why the compo-
nent is offline or not equipped,
consult operating company per-
sonnel. Continue as directed by
operating company personnel.
step 23
DN
STA F S LTA
621 1134 MB
Do
step 10
step 23
TE
RESULT
TE
RESULT