1-272 XPM card replacement procedures (continued)
NT8X18
in an SMS-R
(continued)
Replacing an NT8X18 in an SMS-R
At your current location
1
2
At the MAP display
3
4
297-8021-547 Standard 14.02 May 2001
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
CAUTION
Loss of service
When replacing a card in the SMS-R, ensure that the unit in
which you are replacing the card is inactive and that the mate
unit is active.
Obtain a replacement card. Verify that the replacement card has the same
product engineering code (PEC), including suffix, as the card that is to be
removed.
Access the PM level of the MAP display by typing
>MAPCI;MTC;PM;POST SMSR smsr_no
and pressing the Enter key.
where
smsr_no
is the number of the SMS-R to be posted
Example of a MAP response
SMSR 3
INSV
Unit0
Act
Unit1
InAct
By observing the MAP display, ensure that the card to be removed is on the
inactive unit.
If faulty card is on
active unit
inactive unit
LINKS_OOS
CSIDE 0
InSv
ISTb
Do
step 5
step 8
PSIDE 0