Nortel DMS-100 Series Replacement Procedures page 416

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-384 XPM card replacement procedures (continued)
NTBX01
in an RSC-S (DS-1) Model A RCC2
4
5
6
At the RCE frame
7
297-8021-547 Standard 14.02 May 2001
CM
MS
IOD
Net
.
.
.
RCC2
SysB
0 Quit
PM
2 Post_
RCC2
3 ListSet
4
RCC2
0 ISTb
5 TRNSL
Unit0:
Inact InSv
6 TST
Unit1:
Act InSv
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
13
14 QueryPM
15
16
17
18
By observing the MAP display, ensure that the card to be removed is on the
inactive unit.
If faulty card is on
active unit
inactive unit
Switch the processing activity (SWACT) to the inactive unit by typing
>SWACT
and pressing the Enter key.
Confirm the system prompt by typing
>YES
and pressing the Enter key.
After both units are in service, proceed to the next step.
Place a sign on the active unit bearing the words Active unit—Do not touch.
This sign should not be attached by magnets or tape.
(continued)