Nortel DMS-100 Series Replacement Procedures page 232

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-200 XPM card replacement procedures (continued)
NT7X05
in an RSC-S (DS-1) Model A RCC2
Replacing a/an NT7X05 in RSC-S RCC2
At your current location
1
2
At the MAP display
3
297-8021-547 Standard 14.02 May 2001
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
CAUTION
Loss of service
When replacing a card in the RCC2 ensure the unit where
you are replacing the card is INACTIVE and the mate unit is
ACTIVE by observing the INSV and ACTIVE LEDs on each
NTMX77 card.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
Access the PM level and post the RCC2 by typing
>MAPCI;MTC;PM;POST RCC2 rcc2_no
and pressing the Enter key.
where
rcc2_no
is the number of the RCC2 to be busied
Example of a MAP display:
(continued)