1-992 XPM card replacement procedures (continued)
NTMX72
in an RSC-S (PCM-30) Model A RCO2
20
21
22
23
24
25
297-8021-547 Standard 14.02 May 2001
If RTS
failed
Remove the sign from the active RCO2 unit.
Send any faulty cards for repair according to local procedure.
Record the date the card was replaced, the serial number of the card, and the
symptoms that prompted replacement of the card. Go to step 25.
Return to the procedure that directed you to this procedure. At the point
where a faulty card list was produced, identify the next faulty card on the list
and go to the appropriate card replacement procedure for that card in this
manual.
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
(end)