Nortel DMS-100 Series Replacement Procedures page 896

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-864 XPM card replacement procedures (continued)
NTEX54
in a STAR
(continued)
FSP front panel layout
0 1 8 9 18 19 26 27
ABS
MINOR MAJOR CRITICAL
RCP0
RCP1
Phone 0 Phone 1
RS232
At the MAP terminal
23
24
297-8021-547 Standard 14.02 May 2001
a
Insert the +5V fuse.
b
Insert the +15V fuse.
c
Insert the -48V fuse.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
–48 V
+15 V
+5 V
A maintenance flag (Mtce) can appear. This flag indicates that
system-initiated maintenance tasks are in progress. To stop the
system-initiated maintenance tasks, type
>ABTK
and press the Enter key.
To return the logical drawer to service, type
>RTS
DRWR
drwr_no
and press the Enter key.
where
drwr_no
is the logical drawer number (0 to 17)
Example of a MAP response:
OSvce Tests Initiated
STAR REM1 00 0 Drwr 4 Tst Passed
STAR REM1 00 0 Drwr 4 Rts Passed
If the RTS command
passes, and you must return the other logical drawer
to service
passes, and the other logical drawer is in service
7.5 A, –48V to
line drawers
3 A, +15 V to
line drawers
2 A, +5 V to line
drawers
Do
step 25
step 26

Advertisement