in an RSC-S (PCM-30) Model A RCO2
4
Ensure the PM level of the MAP display is currently displayed and the RCO2
with the faulty DCH card is posted by typing
>MAPCI;MTC;PM;POST RCO2 rco2_no
and pressing the Enter key.
where
rco2_no
is the number of the RCO2 with the faulty card
Example of a MAP display:
CM
MS
.
.
RCO2
0 Quit
PM
2 Post_
RCO2
3 ListSet
4
RCO2
5 TRNSL
Unit0:
6 TST
Unit1:
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
13
14 QueryPM
15 DCH
16
17
18
5
Refer to the MAP display posted in step 4 to see if the faulty NTBX02 card is
in the active or inactive unit.
If faulty card is in
active unit
inactive unit
6
Switch the processing activity (SWACT) to the inactive unit by typing
>SWACT
and pressing the Enter key.