Nortel DMS-100 Series Replacement Procedures page 740

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-708 XPM card replacement procedures (continued)
NTBX72
in an RSC-S (DS-1) Model A LCME
Replacing an NTBX72 card in an RSC-S LCME
At your Current Location
1
2
At the MAP terminal
3
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain an NTBX72 replacement card. Ensure the replacement card has the
same product equipment code (PEC), including suffix, as the card that is to
be removed.
Set the MAP display to the PM level and post the LCME by typing
>MAPCI;MTC;PM;POST LCME site frame_no unit_no
and pressing the Enter key.
where
site
is the name of the site at which the LCME is located
frame_no
is the number of the frame in which the LCME is located
unit_no
is the number of the LCME with the faulty card
Example of a MAP display:
(continued)

Advertisement

Table of Contents
loading

Table of Contents