Nortel DMS-100 Series Replacement Procedures page 234

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-202 XPM card replacement procedures (continued)
NT7X05
in an RSC-S (DS-1) Model A RCC2
7
8
At the RCE frame
9
At the MAP display
10
297-8021-547 Standard 14.02 May 2001
Switch the activity of the unit by typing
>YES
and pressing the Enter key.
The system runs a pre-SWACT audit to determine the ability of the inactive
unit to accept activity reliably.
Note: A maintenance flag appears when maintenance tasks are in
progress. Wait until the flag disappears before proceeding with the next
maintenance action.
If the message is
SwAct passed
SwAct failed
SwAct refused by SwAct con-
troller
Return to the Alarm Clearing Procedure , to clear the alarm condition on the
inactive unit. When the alarm is cleared, return to step 1 of this procedure.
Put a sign on the active unit bearing the words Active unit—Do not touch.
Busy the inactive RCC2 unit by typing
>BSY INACTIVE
and pressing the Enter key.
(continued)
Do
step 9
step 8
step 8