Nortel DMS-100 Series Replacement Procedures page 623

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

f
Continue pulling the card with the extractor until the card is clear of the
shroud.
g
Insert the card removed into the ESD container and store using local
procedures.
8
To replace the card with faults, follow these substeps:
a
Remove the replacement card from the ESD container.
b
Slide the card in the shroud guide slots toward the drawer backplane.
c
Hold the front cover of the line drawer with your left hand to steady it.
d
Grasp the top and bottom edges of the card with the fingers of your right
hand.
e
Push the card toward the backplane until it plugs fully into the backplane
socket.
9
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
At the MAP terminal
10
To test the NTBX27 line card, type
>DIAG
and press the Enter key.
11
Use the following information to determine how to proceed.
If DIAG
passes
fails
12
To return the NTBX27 card to service, type
>RTS
and press the Enter key.
If RTS
passes
fails
13
Send any faulty cards for repair according to local procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in a STAR or RLD
Do
step 15
step 10
Do
step 12
step 16
Do
step 13
step 16
1-591
NTBX27
(continued)

Advertisement

Table of Contents
loading