Nortel DMS-100 Series Replacement Procedures page 1002

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-970 XPM card replacement procedures (continued)
NTMX72
in an RSC-S (DS-1) Model A RCC2
8
At the RCC2 frame
9
10
11
12
297-8021-547 Standard 14.02 May 2001
RCC2
0 ISTb
Unit0:
Inact ManB
Unit1:
Act
ISTb
bsy unit 0
RCC2 0 Unit 0
If the BSY command
passed
failed
Reset the inactive RCC2 unit by typing
>PMRESET
UNIT
unit_no
and pressing the Enter key.
where
unit_no
is the RCC2 unit number (0 or 1)
Example of a MAP response:
RCC2 0 Unit 0
Place a sign on the active unit bearing the words Active unit—Do not touch.
This sign should not be attached by magnets or tape.
Use the following information to determine where to proceed:
If the card you are replacing has
a suffix of
AA
AB
Power down the NTMX72AA power converter by setting the POWER switch
on the NTMX72 card to the OFF position.
Go to step 13.
Power down the NTMX72AB power converter by setting the circuit breaker on
the frame supervisory panel (FSP) for the inactive unit to the OFF position.
(continued)
Links_OOS: CSide
Bsy Passed
Do
step 8
step 24
NORUN
PMReset Passed
Do
step 11
step 12
0 , PSide
1

Advertisement

Table of Contents
loading

Table of Contents