1-510 XPM card replacement procedures (continued)
NTBX02
in an SMA
(continued)
Replacing an NTBX02 card in an SMA
At your Current Location
1
2
3
4
At the MAP terminal
5
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Ensure you know the physical location of the faulty card.
If card location is
known
unknown
Perform the procedure "Locating a faulty card in an SMA."
CAUTION
Loss of service
Ensure that you replace the card in the inactive unit and
verify the mate unit is active.
Obtain a replacement card. Ensure the replacement card has the same
product engineering code (PEC), including suffix, as the card being removed.
Ensure the current MAP display is at the PM level and post the SMA by typing
>MAPCI;MTC;PM;POST SMA sma_no
and pressing the Enter key.
where
sma_no
is the number of the SMA to be posted
Example of a MAP response
Do
step 4
step 3