Nortel DMS-100 Series Replacement Procedures page 376

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-344 XPM card replacement procedures (continued)
NTAX74
in an SMA-MVI-20
26
27
28
29
30
31
32
33
34
35
36
297-8021-547 Standard 14.02 May 2001
(continued)
tape_no
is the number of the tape drive containing the PM load files
Demount the tape drive by typing
>DEMOUNT Ttape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Go to step 38.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP display by typing
>DSKUT
and pressing the Enter key.
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files obtained in
step 28.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 38.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP display by typing
>DISKUT
and pressing the Enter key.
List the SLM disk volumes by typing
>LV CM
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LISTFL volume_name
and pressing the Enter key.

Advertisement

Table of Contents
loading

Table of Contents