Nortel DMS-100 Series Replacement Procedures page 512

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-480 XPM card replacement procedures (continued)
NTBX02
in an RSC-S (DS-1) Model B RCC2
28
29
30
297-8021-547 Standard 14.02 May 2001
and pressing the Enter key.
If RTS
passed
failed
Leave the DCH level of the MAP display and return to the RCC2 level by
typing
>QUIT
and pressing the Enter key.
Return to service the PM unit busied in step 11 by typing
>RTS unit unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCC2 unit (0 or 1) containing the new
BX02 card
Ensure that the RCC2 unit is in service by typing
>QUERYPM FLT
and pressing the Enter key.
Example of a MAP display:
CM
MS
IOD
Net
.
.
.
RCC2
SysB
0 Quit
PM
2 Post_
RCC2
3 ListSet
4
RCC2
0
InSv
5 TRNSL_
Unit0:
Act InSv
6 Tst_
Unit1:
Inact InSv
7 Bsy_
QUERYPM FLT
8 RTS_
Unit0
9 OffL
Unit1
10 LoadPM_
11 Disp_
12 Next
13
14 QueryPM
15 DCH
16
17
18
(continued)
Do
step 28
step 34
PM
CCS
Lns
.
.
.
.
ManB
OffL
0
0
0
0
0
0
Links_OOS:
CSide
No troubles exist
No troubles exist
Trks
Ext
Appl
.
.
.
CBsy
ISTb
InSv
0
0
25
0
0
0, PSide
0
1

Advertisement

Table of Contents
loading

Table of Contents