Nortel DMS-100 Series Replacement Procedures page 966

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-934 XPM card replacement procedures (continued)
NTMX71
in an SMS
(continued)
Replacing a NTMX71 card in a SMS
At your Current Location
1
2
At the MAP terminal
3
4
5
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain a replacement card. Ensure the replacement card has the same
product engineering code (PEC), including suffix, as the card being removed.
Ensure the current MAP display is at the PM level and post the SMS by typing
>MAPCI;MTC;PM;POST SMS sms_no
and pressing the Enter key.
where
sms_no
is the number of the SMS being posted
Example of a MAP response
SMS
SysB
ManB
PM
3
0
SMS
0
0
SMS 0 ISTb
Links_OOS:
Unit0:
Act
InSv
Unit1:
Inact ISTb
Observe the MAP display and determine if the faulty card is in the active or
the inactive unit. The example in step 3 shows the status of the PM as
in-service (InSv) on the active unit and in-service trouble (ISTb) on the
inactive unit.
If the faulty card is in the
active unit
inactive unit
Switch the activity of the units by typing
>SWACT
and pressing the Enter key.
Offl
CBsy
ISTb
1
0
2
0
0
1
CSide 0, PSide 0
Do
step 5
step 12
InSv
13
7

Advertisement

Table of Contents
loading

Table of Contents