Nortel DMS-100 Series Replacement Procedures page 565

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the frame:
10
Put a sign on the active unit bearing the following words: "Active unit-Do not
touch."
At the MAP terminal:
11
Busy the inactive unit by typing
>bsy unit unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive SMU unit (0 or 1) containing the faulty
BX02 card
12
Access the DCH level of the MAP display by typing
>DCH
and pressing the Enter key.
13
Post all DCH cards by typing
>POST ALL
and pressing the Enter key
14
Identify the faulty DCH card by typing
>DISP ALL
and pressing the Enter key
Example of a MAP response:
DCH
8 ISG
DCH
9 spare
15
Post the faulty DCH card by typing
>POST dch_card_state
and pressing the Enter key.
where
dch_card_state
is Cbsy, SysB, or ISTb
Example of a MAP display:
DCH
8
Note: Record the number of the faulty DCH card for later use in this
procedure.
16
Identify the DCH load file name by typing
>QUERYPM
and pressing the Enter key.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
4 CBsy SMU
InSv SMU
ISG 1
CBSY SMU
in an SMU
1 port 17
1 port 19
1
PORT 17
1-533
NTBX02
(continued)