Nortel DMS-100 Series Replacement Procedures page 42

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-10 XPM card replacement procedures (continued)
NT6X85
in an SMS
(continued)
At the MAP terminal
16
17
18
297-8021-547 Standard 14.02 May 2001
If
no protection lines were busied
Return all busied protection lines to service by typing
>RTS line_no
and pressing the Enter key.
where
line_no
is the number of the protection line connected to the new NT6X85 card
Repeat this command for each busied protection line.
If
no protection line returned to
service
one protection line returned to
service and another link was
busied at the PM level
two protection lines returned to
service
Return all busied links to service by typing
>RTS LINK link_no
and pressing the Enter key
where
link_no
is the number of the link connected to the faulty NT6X85 card
Repeat this command for each busied link.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Do
step 17
Do
step 21
step 9, then step 17
step 17
Do
step 18
step 21

Advertisement

Table of Contents
loading