Nortel DMS-100 Series Replacement Procedures page 138

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-106 XPM card replacement procedures (continued)
NT6X92
in an RSC-S (PCM-30) Model B RCO2
Replacing an NT6X92 card in an RSC-S RCO2
At your Current Location
1
2
3
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
CAUTION
Loss of service
When replacing a card in the RCO2, ensure that the unit in
which you are replacing the card is inactive and that the mate
unit is active.
Obtain an NT6X92 replacement card. Ensure the replacement card has the
same product equipment code (PEC), including suffix, as the card that is to
be removed.
Ensure the PM level of the MAP display is currently displayed and the RCO2
is posted by typing
>MAPCI;MTC;PM;POST RCO2 rco2_unit_no
and pressing the Enter key.
where
rco2_unit_no
is the number of the RCO2 with the faulty card
Example of a MAP display:
(continued)