Summary of card replacement procedure for NT6X99 card in an ILCM
At the LTP level,
post the line.
Is the line
status ManB?
Busy the line.
Replace the line
card.
Test the line.
Did the
test pass?
Obtain assistance
from maintenance
support group.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
Y
N
Y
N
XPM card replacement procedures (continued)
in an IOPAC ILCM
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.
Return the line to
service.
Did return to
service pass?
N
Obtain assistance
from maintenance
support group.
NT6X99
(continued)
Y
End of the
procedure