Nortel DMS-100 Series Replacement Procedures page 151

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Summary of card replacement procedure for an NT6X92 card in an SMA
Post the PM
Faulty card is
N
in the active
unit?
Y
Switch activity
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
N
Is the faulty
unit status
ManB?
Y
Replace the
faulty card
Return to the
original alarm
procedure
Return to the
Y
procedure that
directed you
here
in an SMA-MVI-20
This flowchart summarizes the
procedure.
Use the instructions in the step-action
procedure that follows this flowchart to
perform the procedure.
Busy unit
Replace the
faulty card
From alarm
N
clearing
procedure?
Y
Load unit
N
Load passed?
Y
Return the unit
to service
Return to
N
service
passed?
1-119
NT6X92
(continued)
Return to the
original alarm
procedure
Return to card
list or contact
next level of
support
Contact next
level of support