Nortel DMS-100 Series Replacement Procedures page 280

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-248 XPM card replacement procedures (continued)
NT7X05
in an SMS-R
(continued)
At the frame
10
11
297-8021-547 Standard 14.02 May 2001
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the left side of the
frame supervisory panel of the SMS-R. This protects the
equipment against damage caused by static electricity.
DANGER
Equipment damage
Take the following precautions when removing or inserting a
card:
1. Do not apply direct pressure to the components.
2. Do not force the cards into the slots.
Put on a wrist strap.
Remove the NT7X05 card as shown in the following figures.
a
Locate the card to be removed on the appropriate shelf.
b
Open the locking levers on the card to be replaced and gently pull the
card towards you until it clears the shelf.

Advertisement

Table of Contents
loading

Table of Contents