Nortel DMS-100 Series Replacement Procedures page 174

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-142 XPM card replacement procedures (continued)
NT6X92
in an SMU
(continued)
Replacing an NT6X92 card in an SMU
At your current location:
1
2
At the MAP terminal:
3
4
5
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
CAUTION
Loss of service possible
When replacing a card in the SMU, ensure that the unit
where you are replacing the card is inactive and that the mate
unit is active.
Get a replacement card. Ensure the replacement card has the same product
engineering code (PEC), including suffix, as the card to be removed.
Access the PM level of the MAP terminal and post the faulty SMU by typing
>MAPCI;MTC;PM;POST SMU smu_no
and pressing the Enter key.
where
smu_no
is the number of the SMU
Example of a MAP display response:
SMU 3
INSV
Unit0
Act
Unit1
Inact
By observing the MAP display, ensure the card to be removed is on the
inactive unit.
If faulty card is on
active unit
inactive unit
Switch the activity of the units by typing
>SWACT
LINKS_OOS
CSIDE
InSv
SysB
Do
step 5
step 8
PSIDE O

Advertisement

Table of Contents
loading