Nortel DMS-100 Series Replacement Procedures page 651

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

10
Use the following information to determine where to proceed.
If load
passed
failed
11
Test the LCME unit by typing
>TST UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the LCME unit loaded in step 9
12
Use the following information to determine where to proceed.
If TST
passed
failed
13
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
14
Return the LCME unit to service by typing
>RTS UNIT lcme_unit_no
and pressing the Enter key.
where
lcme_unit_no
is the number of the LCME unit tested in step 12
15
Use the following information to determine where to proceed.
If RTS
passed
failed
16
Send any faulty cards for repair according to local procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC-S (DS-1) Model B LCME
Do
step 11
step 19
Do
step 13
step 18
Do
step 18
step 14
Do
step 16
step 19
1-619
NTBX34
(continued)