Nortel DMS-100 Series Replacement Procedures page 328

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-296 XPM card replacement procedures (continued)
NTAX74
in an RSC-S (DS-1) Model B RCC2
4
5
6
297-8021-547 Standard 14.02 May 2001
CM
MS
IOD
.
.
.
RCC2
SysB
0 Quit
PM
2 Post_
RCC2
3 ListSet
4
RCC2
0 ISTb
5 TRNSL_
Unit0:
Inact SysB
6 TST_
Unit1:
7 BSY_
8 RTS_
9 OffL
10 LoadPM_
11 Disp_
12 Next_
13 SwAct
14 QueryPM
15
16 IRLINK
17 Perform
18
To verify the defective NTAX74 card is in the inactive unit, make sure the
light-emitting diode (LED) labled ACTIVE is OFF or check the MAP display.
If the defective card
is in the active unit
is in the inactive unit
To switch the processing activity (SWACT) to the inactive unit, type:
>SWACT
and press the Enter key.
A confirmation prompt for the SWACT command appears at the MAP
terminal.
If SWACT
cannot continue at this time
can continue at this time
To reject the prompt to SWACT the units, type:
>NO
and press the Enter key.
The system stop the SWACT.
Return to step 5 during periods of low traffic.