Nortel DMS-100 Series Replacement Procedures page 156

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-124 XPM card replacement procedures (continued)
NT6X92
in an SMA-MVI-20
18
At the equipment frame
19
20
21
22
23
297-8021-547 Standard 14.02 May 2001
(end)
If TST
failed
Return the inactive SMA unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the SMA unit tested in step 17
If RTS
passed
failed
Remove the sign from the active SMA unit.
Send any faulty cards for repair according to local procedure.
Note the following in the office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 23.
For further assistance, contact the personnel responsible for the next level of
support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.