Nortel DMS-100 Series Replacement Procedures page 499

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

29
Return to service the PM unit busied in step 11 by typing
>RTS unit unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCC2 unit (0 or 1) containing the new
BX02 card
30
Ensure that the RCC2 unit is in service by typing
>QUERYPM FLT
and pressing the Enter key.
Example of a MAP display:
CM
MS
.
.
RCC2
0 Quit
2 Post_
3 ListSet
4
5 TRNSL_
6 Tst_
7 Bsy_
8 RTS_
9 OffL
10 LoadPM_
11 Disp_
12 Next
13
14 QueryPM
15 DCH
16
17
18
Use the following information to determine the next step in this procedure.
If faults are
not indicated
indicated
31
Send any faulty cards for repair according to local procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 6 of 7 LET0015 and up
XPM card replacement procedures (continued)
in an RSC-S (DS-1) Model A RCC2
IOD
Net
PM
.
.
.
SysB
ManB
PM
0
0
RCC2
0
0
RCC2
0
InSv
Links_OOS:
Unit0:
Act InSv
Unit1:
Inact InSv
QUERYPM FLT
Unit0
No troubles exist
Unit1
No troubles exist
CCS
Lns
Trks
.
.
.
OffL
CBsy
0
0
0
0
CSide
0, PSide
Do
step 31
step 34
1-467
NTBX02
(continued)
Ext
Appl
.
.
ISTb
InSv
0
25
0
1
0