1-32 XPM card replacement procedures (continued)
NT6X86
in an SMS
(continued)
Replacing an NT6X86 card in an SMS
At your Current Location
1
2
At the MAP terminal
3
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
CAUTION
Loss of service
When replacing a card in the SMS, ensure the unit where you
are replacing the card is inactive and the mate unit is active.
Obtain a replacement card. Verify the replacement card has the same
product engineering code (PEC), including suffix, as the card to be removed.
Note: When the SMS peripheral is equipped with XPM PLUS
(NTMX77AA Unified Processor), the NT6X86AB card is required. The
6X86AB is backward compatible and can be used with the Master
Processor/Signal Processor (MP/SP) complex (NT6X45, 6X46, 6X47).
The 6X86AA version can be used only in MP/SP SMSs and cannot be
used in XPM PLUS equipped SMSs. When replacing the NT6X86 card,
ensure the correct card is replaced with the appropriate AA or AB version.
Access the PM level of the MAP display by typing
>MAPCI;MTC;PM;POST SMS sms_no
and pressing the Enter key.
where
sms_no
is 0-127 for NT40 and 0-255 for DMS SuperNode
Example of a MAP response
SMS 3
INSV
LINKS_OOS
Unit0
Act
Unit1
Inact
CSIDE 0
InSv
ISTb
PSIDE 0

Advertisement