Nortel DMS-100 Series Replacement Procedures page 292

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-260 XPM card replacement procedures (continued)
NT7X05
in an SMU
(end)
16
17
18
19
20
21
297-8021-547 Standard 14.02 May 2001
unit_no
is the number of the SMU unit (0 or 1) tested in step 14
If load
passed
failed
Load the inactive SMU unit by typing
>LOADPM INACTIVE CC XPMSTOR [file_name]
and pressing the Enter key.
where
file_name
is the name of the file datafilled in field, LOAD, of the inventory table.
If load
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 20.
Obtain further assistance in replacing this card by contacting personnel
responsible for higher level of support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
For further assistance with switch of activity, contact the personnel
responsible for the next level of support.
Note: If the system recommends using the SWACT command with the
FORCE option, consult office personnel to determine if use of the FORCE
option is advisable.
Do
step 16
step 19
Do
step 17
step 19