1-134 XPM card replacement procedures (continued)
NT6X92
in an SMS
(continued)
Replacing an NT6X92 card in an SMS
At your Current Location
1
2
At the MAP terminal
3
4
5
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
CAUTION
Loss of service
When replacing a card in the SMS, ensure the unit where you
are replacing the card is inactive and the mate unit is active.
Obtain a replacement card. Verify the replacement card has the same
product engineering code (PEC), including suffix, as the card to be removed.
Access the PM level of the MAP display and post the faulty SMS by typing
>MAPCI;MTC;PM;POST SMS sms_no
and pressing the Enter key.
where
sms_no
is 0-127 range for NT40 and 0-255 range for DMS SuperNode
Example of a MAP response
SMS 3
INSV
Unit0
Act
Unit1
Inact
By observing the MAP display, be sure the card to be removed is on the
inactive unit.
If faulty card is on
active unit
inactive unit
Switch the activity of the units by typing
>SWACT
LINKS_OOS
CSIDE 0
InSv
ISTb
Do
step 5
step 8
PSIDE 0