Nortel DMS-100 Series Replacement Procedures page 66

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-34 XPM card replacement procedures (continued)
NT6X86
in an SMS
(continued)
At the frame
8
At the MAP terminal
9
At the frame
10
11
297-8021-547 Standard 14.02 May 2001
Put a sign on the active unit bearing the words: Active unit—Do not touch .
This sign should not be attached by magnets or tape.
Busy the inactive PM unit by typing
>bsy
unit unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the left side of the
frame supervisory panel of the SMS. This protects the
equipment against damage caused by static electricity.
Put on a wrist strap.
DANGER
Equipment damage
When removing or inserting a card, do not apply pressure to
the components and do not force the cards into the slots.
Remove the NT6X86 card as shown in the following figures.
a
Locate the card to be removed on the appropriate shelf.

Advertisement

Table of Contents
loading

Table of Contents