Nortel DMS-100 Series Replacement Procedures page 132

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-100 XPM card replacement procedures (continued)
NT6X92
in an RSC-S (PCM-30) Model A RCO2
At the RCE frame
9
10
297-8021-547 Standard 14.02 May 2001
WARNING
Static electricity damage
Before removing any cards, put on a wrist strap and connect
it to the wrist strap grounding point on the left side of the
modular supervisory panel of the RCO2. This protects the
equipment against damage caused by static electricity.
DANGER
Equipment damage
Take these precautions when removing or inserting a card:
1. Do not apply direct pressure to the components.
2. Do not force the card into its slot.
Put on a wrist strap.
Remove the NT6X92 card as shown in the following figures.
a
Locate the card to be removed on the appropriate shelf.
b
Open the locking levers on the card to be replaced and gently pull the
card toward you until it clears the shelf.
(continued)