1-914 XPM card replacement procedures (continued)
NTMX71
in an RSC
(continued)
24
25
At the equipment frame
26
27
28
297-8021-547 Standard 14.02 May 2001
where
rcc_unit_no
is the number of the inactive RCC unit
If the load
passed
failed
Load the inactive RCC unit by typing
>LOADPM UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCC unit
If load
passed
failed
Return the inactive RCC unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the inactive RCC unit
If RTS
passed
failed
Remove the sign from the active RCC unit.
Send any faulty cards for repair according to local procedure.
Note the following in the office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 30.
Do
step 25
step 24
Do
step 25
step 29
Do
step 26
step 29