1-298 XPM card replacement procedures (continued)
NTAX74
in an RSC-S (DS-1) Model B RCC2
At the RCE frame
13
14
297-8021-547 Standard 14.02 May 2001
WARNING
Static electricity damage
Before you remove cards, wear a wrist strap that connects to
the wrist-strap grounding point on the left side of the frame
supervisory panel (FSP) of the RCC2. This protects the
equipment against static electricity damage.
DANGER
Equipment damage
Take the following precautions when you remove or insert a
card:
1. Do not apply direct pressure to the components.
2. Do not force the cards into the slots.
Wear a wrist strap.
The following figures show how to remove the NTAX74 card:
a
Locate the card to be removed on the appropriate shelf.
b
Open the locking levers on the card to be replaced. Carefully pull the
card toward you until the card clears the shelf.
(continued)