Omron NX701-17 Series Troubleshooting Manual page 87

Machine automation controller nj/nx-series
Hide thumbs Also See for NX701-17 Series:
Table of Contents

Advertisement

Event code
Event name
04020000 hex
PLC System
Information
44410000 hex
PLC System
Information
Errors Related to the Built-in I/O and Option Boards
The manual names are given below for the catalog numbers given in the Reference column of the
event table.
Cat. No.
W579
Event code
Event name
05440000 hex
Option Board
(Ver. 1.13 or
Error
later)
35940000 hex
Option Board
(Ver. 1.13 or
Configura-
later)
tion Verifica-
tion Error
35950000 hex
Unsupported
(Ver. 1.13 or
Option Board
later)
Mounted
88130000 hex
Analog
(Ver. 1.13 or
Option Board
later)
Startup Error
88140000 hex
Analog
(Ver. 1.13 or
Option Board
later)
Communica-
tions Error
NJ/NX-series Troubleshooting Manual (W503)
Meaning
Assumed cause
This event pro-
• This event provides internal
vides internal infor-
information from the PLC Func-
mation from the
tion Module. It is recorded to
PLC Function Mod-
provide additional information
ule.
for another event.
This event pro-
• This event provides internal
vides internal infor-
information from the PLC Func-
mation from the
tion Module. It is recorded to
PLC Function Mod-
provide additional information
ule.
for another event.
NX-series NX1P2 CPU Unit Built-in I/O and Option Board User's Manual
Meaning
Assumed cause
An Option Board
• An Option Board was removed
was removed or
or mounted during operation.
mounted during
• A hardware error was detected
operation, or an
in an Option Board.
Option Board hard-
ware error
occurred.
The Option Board
• The Option Board configura-
configuration setup
tion setup does not agree with
does not agree with
the actual configuration.
the actual configu-
• An Option Board is not
ration.
mounted correctly.
There is an unsup-
• There is an unsupported Option
ported Option
Board in the actual configura-
Board in the actual
tion.
configuration.
An error occurred
• An Analog Option Board is not
when an Analog
mounted correctly. Or an Ana-
Option Board is
log Option Board failed.
started.
A communications
• If the indicator on an Analog
error occurred
Option Board flashes, it means
during Analog
that an error occurred in com-
Option Board oper-
municating with the Analog
ation.
Option Board during operation.
• If the indicator on an Analog
Option Board is lit, it means that
a WDT error occurred in the
Analog Option Board.
Level
Maj
Prt
Min
Obs Info
Manual name
Level
Maj
Prt
Min
Obs Info
S
S
S
S
S
3 Error Tables
Reference
S
W500
S
W500
3
Reference
W579
W579
W579
W579
W579
3-9

Advertisement