3 Error Tables
Event code
Event name
572B0000 hex
Number of
(Ver. 1.06 or
Array Ele-
later)
ments in
Switch Struc-
ture Variable
Out of Range
572C 0000 hex
Number of
(Ver. 1.06 or
Array Ele-
later)
ments in Out-
put Signal
Structure
Variable Out
of Range
572D 0000 hex
Number of
(Ver. 1.06 or
Array Ele-
later)
ments in
Track Option
Structure
Variable Out
of Range
572E0000 hex
Numbers of
(Ver. 1.06 or
Elements in
later)
Output Sig-
nals and
Track Option
Arrays Not
Matched
57310000 hex
Same Track
(Ver. 1.06 or
Number Set-
later)
ting in Switch
Structure Out
of Range
3-94
Meaning
Assumed cause
The number of ele-
• The number of elements in an
ments in an array in
array of the structure variable
the structure vari-
that was specified for the in-out
able that is speci-
variable of the instruction is out
fied in the Switches
of range.
in-out variable to a
motion control
instruction is out of
range.
The number of ele-
• The number of elements in an
ments in an array in
array of the structure variable
the structure vari-
that was specified for the in-out
able that is speci-
variable of the instruction is out
fied in the Outputs
of range.
in-out variable to a
motion control
instruction is out of
range.
The number of ele-
• The number of elements in an
ments in an array in
array of the structure variable
the structure vari-
that was specified for the in-out
able that is speci-
variable of the instruction is out
fied in the
of range.
TrackOptions in-out
variable to a motion
control instruction is
out of range.
The arrays in the
• The arrays in the output signal
structure variables
structure variable and track
that are specified
option structure variable that
for the Outputs and
are specified for the in-out vari-
TrackOptions in-out
ables to the instruction do not
variables to a
have the same number of ele-
motion control
ments.
instruction do not
have the same
number of ele-
ments.
The same track
• The same track number was
number was speci-
specified more than the allow-
fied more than the
able number of times for the
allowable number
TrackNumber in the Switches
of times for the
in-out variable to a motion con-
TrackNumber in the
trol instruction.
Switches in-out
variable to a motion
control instruction.
Level
Maj
Prt
Min
Obs Info
S
S
S
S
S
NJ/NX-series Troubleshooting Manual (W503)
Reference
W508