Event code
Event name
5401381B hex
Insufficient
Transaction
Resource
54013820 hex
Too Many Char-
acters
54013821 hex
Invalid Size
54013822 hex
Set to Disable
54013824 hex
Undefined CEID
54013825 hex
Undefined ALID
54013826 hex
Undefined
CCODE
54013827 hex
Undefined Mes-
sage Number
54013828 hex
HSMS Commu-
nications Set-
ting Out of
Range
54013829 hex
TID Out of
Range
5401382C hex
Undefined ECID
5401382D hex
Type Mismatch
5401382E hex
ECV Out of
Range
NJ/NX-series Troubleshooting Manual (W503)
Meaning
Assumed cause
The instruction was
• The instruction was exe-
executed while the
cuted while the number
number of transac-
of transactions that can
tions that can be buff-
be buffered exceeds the
ered exceeds the
upper limit.
upper limit.
More characters were
• More characters were
specified than the num-
specified than the num-
ber that was set and
ber of characters set with
the instruction was
the SECS/GEM Configu-
executed.
rator.
An incorrect array or an
• A value was specified
array with an incorrect
that is larger than the
number of elements
maximum table size set
was specified and the
with the SECS/GEM
instruction was exe-
Configurator.
cuted.
The instruction that
• The instruction executed
was set to disable was
for a GEM capability was
executed.
disabled on the
SECS/GEM Configura-
tor.
An undefined CEID
• A CEID that was not
was specified and the
defined in the
instruction was exe-
SECS/GEM Configura-
cuted.
tor was specified.
An undefined ALID
• An ALID that was not
was specified and the
defined in the
instruction was exe-
SECS/GEM Configura-
cuted.
tor was specified.
An undefined CCODE
• A CCODE that was not
was specified and the
defined in the
instruction was exe-
SECS/GEM Configura-
cuted.
tor was specified.
An undefined mes-
• A message number that
sage number was
was not defined in the
specified and the
SECS/GEM Configura-
instruction was exe-
tor was specified.
cuted.
An HSMS communica-
• An HSMS communica-
tions setting that is out
tions setting that is out of
of range was specified
range was specified.
and the instruction was
executed.
A TID that is out of
• A TID that is out of range
range was specified
was specified.
and the instruction was
executed.
An undefined ECID
• An ECID that was not
was specified and the
defined in the
instruction was exe-
SECS/GEM Configura-
cuted.
tor was specified.
A value with an incor-
• A different equipment
rect data type was
constant data type than
specified and the
the one registered with
instruction was exe-
the SECS/GEM Configu-
cuted.
rator was specified.
An out-of-range value
• A value was specified
was specified for an
that is outside the upper
equipment constant
and lower limits of the
and the instruction was
value of the equipment
executed.
constant that was set on
the SECS/GEM Configu-
rator.
3 Error Tables
Level
Maj
Prt
Min
Obs
Info
S
S
S
S
S
S
S
S
S
S
S
S
S
Refer-
ence
W528
W528
W528
3
W528
W528
W528
W528
W528
W528
W528
W528
W528
W528