3 Error Tables
Event code
Event name
385A0000 hex
Change in
Connected
Camera
385B0000 hex
Light installa-
tion error
48020000 hex
System Error
58210000 hex
Output Con-
trol Timeout
for Parallel
I/O, PLC
Link, or Eth-
erNet/IP
58220000 hex
Output Con-
trol Timeout
for EtherCAT
58230000 hex
Initial scene
group error
58240000 hex
Initial scene
number error
78190000 hex
Image Log-
ging Disk
Write Error
3-218
Meaning
Assumed cause
The Camera that is
• The Camera connection infor-
connected is differ-
mation in the scene data does
ent from when data
not agree with the connection
was last saved.
information for the Camera con-
nected to the Controller.
The Light installa-
• The power consumption of the
tion is incorrect.
light installed onto a camera
with a Lighting Controller is
incorrect.
• The lighting mode of the light
installed onto a camera with a
Lighting Controller is incorrect.
• No external power supply is
connected to the camera with a
Lighting Controller.
An error occurred in
• A serious error occurred in the
the system.
system in the Controller.
A timeout occurred
• The data output handshaking
in data output hand-
controls in the program (i.e., the
shaking control for
ON/OFF timing of the DSA sig-
measurement
nal) are not correct.
results.
• The output control timeout time
is too short in comparison with
the program processing time.
• The parallel I/O DSA or Result
Notification signal is not wired
correctly.
A timeout occurred
• The data output handshaking
in data output hand-
controls in the program (i.e., the
shaking control for
ON/OFF timing of the Result
measurement
Set Request signal) are not cor-
results.
rect.
• The output control timeout time
is too short in comparison with
the program processing time.
Initial scene group
• The external storage specified
setting is incorrect.
as the scene group destination
by the Scene Group Saving
Destination Settings tool is not
connected at the time of
startup.
• The destination directory is not
detected at the time of startup.
• Initial scene group number is
not within the range of scene
group accepted by the system.
Initial scene num-
• Initial scene number is not
ber setting is incor-
within the range of scenes
rect.
accepted by the system.
Writing data to the
• A logging disk is not inserted.
image logging disk
• The available space on the log-
failed.
ging disk is not sufficient.
• There is no logging folder.
• Security restrictions are set on
the logging disk.
Level
Maj
Prt
Min
Obs Info
S
S
S
S
S
S
S
S
NJ/NX-series Troubleshooting Manual (W503)
Reference
Z342
Z342
Z342
Z342
Z342
Z342
Z342
Z342

Advertisement