Event code
Event name
54012C05 hex
NX Message Eth-
(Ver. 1.05 or
erCAT Network
later)
Error
54012C06 hex
External Restart
(Ver. 1.05 or
Already Executed
later)
for Specified NX
Units
54012C07 hex
Unapplicable Unit
(Ver. 1.05 or
Specified for
later)
Instruction
54012C08 hex
Invalid Total Power
(Ver. 1.10 or
ON Time Record
later)
54013461 hex
Process Data
Object Setting
Missing
54014800 hex
Device Error
Received
(Ver. 1.12 or
later)
54014801 hex
Specified Unit
Does Not Exist
(Ver. 1.12 or
later)
54014802 hex
Message Process-
ing Limit Exceeded
(Ver. 1.12 or
later)
54014803 hex
Specified Unit Sta-
tus Error
(Ver. 1.12 or
later)
54014804 hex
Too Many Simulta-
neous Instruction
(Ver. 1.12 or
Executions
later)
NJ/NX-series Troubleshooting Manual (W503)
Meaning
An error occurred in Ether-
• An error occurred in
CAT communications on
the NX message path.
A restart was already in
• A restart was already
execution from the Sys-
mac Studio when the
instruction was executed.
A slave that cannot be
• A slave that cannot be
specified for the instruction
was connected at the slave
node address of the speci-
fied Unit.
The total power ON time
• Non-volatile memory
could not be read.
The PDO mapping is not
• The PDOs that are
correct.
• The relevant instruc-
• A motion control
An error response from the
• An error response
device was received.
The specified Unit does not
• The IO-Link master is
exist.
An instruction cannot be
• An instruction cannot
executed because the IO-
Link master is processing
the message from another
application.
The specified Unit is not in
• The specified Unit is
a condition to receive mes-
sages.
The number of instructions
• More than 32 NX mes-
that can be simultaneously
executed was exceeded.
Assumed cause
Maj
Prt
EtherCAT communica-
tions on the NX mes-
sage path.
in execution from the
Sysmac Studio when
the instruction was
executed.
specified for the
instruction was con-
nected to the slave
node address of the
specified Unit.
failure
required for the motion
control instruction are
not mapped.
tion was executed for
a device that does not
have an object that
supports the instruc-
tion.
instruction that speci-
fies phase Z (_mcEn-
coderMark) as the
trigger conditions was
executed for an axis
that is mapped to an
OMRON GX-
EC02 EtherCAT
Encoder slave.
from the device was
received.
not connected to or
mounted on the speci-
fied position.
be executed because
the IO-Link master is
processing the mes-
sage from another
application (an instruc-
tion execution or a tool
connection).
not in a condition to
receive messages.
sage instructions and
EtherCAT communica-
tions instructions were
executed at the same
time.
3 Error Tables
Level
Refer-
ence
Min
Obs
Info
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
S
W502
3-39
3