Omron NX701-17 Series Troubleshooting Manual page 270

Machine automation controller nj/nx-series
Hide thumbs Also See for NX701-17 Series:
Table of Contents

Advertisement

3 Error Tables
Event code
Event name
84860000 hex
Warning-level
Device Event
Flag
84820000 hex
IO-Link
Device Con-
figuration
Information
Created
84850000 hex
I/O Power
Supply ON
Detected
Servo 1S (1S-series AC Servo Drives with Built-in EtherCAT
Communications) R88M-1 and R88D-1SN-ECT
The section provides a table of the errors (events) that can occur in R88M-1 (AC Servomotors) or
R88D-1SN-ECT (AC Servo Drives).
The manual name is given below for the catalog numbers given in the Reference column of the event
table.
Cat. No.
I586
Event code
Event name
05430000 hex
ESC Error
08390000 hex
Power Mod-
ule Error
083B0000 hex
Self-diagno-
sis Error
083C 0000 hex
Main Circuit
Temperature
Monitoring
Circuit Fail-
ure
3-192
Meaning
A warning-level
Use CX-Configurator FDT to con-
event occurred in
firm the event code of the IO-Link
the IO-Link
device.
device.
IO-Link device
IO-Link device configuration infor-
configuration
mation was created.
information was
created.
The I/O power
The I/O power supply ON was
supply ON was
detected in several times.
detected in sev-
eral times.
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT Communications User's Man-
ual
Meaning
An error occurred
• Error of the EtherCAT slave
in the EtherCAT
communications controller or
slave communi-
false detection when the AL
cations controller.
status code is 0051 hex
• Error access from the non-
OMRON EtherCAT master
when the AL status code is
0050 hex
An error was
• There is a short-circuit, ground
detected in the
fault, or contact failure on the U,
power module.
V, or W motor cable
• There is a short-circuit on the
wiring of External Regenera-
tion Resistor or the resistance
value is small
• The insulation resistance failed
between the U, V, or W motor
cable and the motor ground
wire
• Servo Drive failure
An error was
• False detection due to a data
detected by the
read error that was caused by
self-diagnosis of
excessive noise
the safety func-
• Hardware failure
tion.
A temperature
• Broken wiring of the thermistor,
monitoring circuit
temperature monitoring circuit
failure was
failure
detected on the
main circuit.
Assumed cause
Maj
Manual name
Assumed cause
Maj
NJ/NX-series Troubleshooting Manual (W503)
Level
Refer-
ence
Prt
Min
Obs
Info
S
W570
S
W570
S
W570
Level
Refer-
ence
Prt
Min Obs Info
S
I586
S
I586
S
I586
S
I586

Advertisement

Table of Contents
loading

Table of Contents