Omron NX701-17 Series Troubleshooting Manual page 51

Machine automation controller nj/nx-series
Hide thumbs Also See for NX701-17 Series:
Table of Contents

Advertisement

Error Resetting Methods
Method
Commands from
Sysmac Studio
Commands from an
*2
HMI
Commands from the
user program
Commands from a
host computer
NJ/NX-series Troubleshooting Manual (W503)
Errors that are
Operation
reset
Resetting Controller
Resetting all errors
errors
in the entire Control-
ler
Resetting all Slave
Terminal errors
Resetting errors for
individually speci-
fied NX Units
Downloading
Resetting all errors
for a specific func-
tion module
Clear All Memory
Resetting all errors
for all function mod-
ules
Controller reset
Clear All Memory
Resetting all Slave
operation for Slave
Terminal errors
Terminal
Restarting the Slave
Terminal
Resetting Controller
Resetting all errors
errors
in the entire Control-
ler
Resetting Controller
Resetting errors for
errors
individual function
modules
Resetting Controller
Resetting all errors
errors with CIP mes-
for all function mod-
sages
ules
1 Overview of Errors
Description
Reset the Controller errors from the Sys-
mac Studio's Troubleshooting Dialog Box.
Refer to the manual for the Communica-
tions Coupler Unit for details on resetting
errors in a Slave Terminal.
For NX Units connected to the NX bus of
the CPU Unit, reset the Controller error indi-
vidually from the Sysmac Studio's Trouble-
shooting Dialog Box.
Refer to the manual for the Communica-
tions Coupler Unit for details on resetting
errors individually for NX Units mounted to
a Slave Terminal.
After the causes of the Controller errors are
removed, all Controller errors in the rele-
vant function module are reset as a result.
Errors are not reset when you download the
Controller Configurations and Setup.
After the causes of the Controller errors are
removed, all Controller errors in all function
modules are reset as a result. Errors for
Slave Terminals are not reset.
After the causes of the Controller errors are
removed, all Controller errors in all function
modules are reset as a result. Errors for
Slave Terminals are not reset.
If the causes for the Controller errors are
removed, all Controller errors in the Slave
Terminals are reset.
Reset Controller errors from the Trouble-
shooter of an HMI.
You can reset errors from an HMI that is not
directly compatible with the NJ/NX-series
Controller or another company's HMI if you
use the HMI in combination with the reset
error instruction for the function module in
the user program.
Execute the reset error instruction for the
function module in the user program.
• For the Motion Control Function Module,
you can reset all errors, errors for a par-
ticular axis, or errors for a particular axes
group.
• For the NJ-series I/O bus, you can reset
all errors or just the errors for a particular
Unit.
• For the NX Bus Function Module, only
resetting all errors is possible.
Use a CIP message from a host computer
to reset errors.
1
*1
*1
1-23

Advertisement

Table of Contents
loading

Table of Contents