3 Error Tables
Event code
Event name
542B0000 hex
Buffer Mode
Selection Out
of Range
542C 0000 hex
Coordinate
System
Selection Out
of Range
542D 0000 hex
Circular Inter-
polation
Mode Selec-
tion Out of
Range
542E0000 hex
Direction
Selection Out
of Range
542F 0000 hex
Path Selec-
tion Out of
Range
54300000 hex
Position Type
Selection Out
of Range
54310000 hex
Travel Mode
Selection Out
of Range
54320000 hex
Transition
Mode Selec-
tion Out of
Range
54330000 hex
Continue
Method
Selection Out
of Range
54340000 hex
Combine
Mode Selec-
tion Out of
Range
3-74
Meaning
Assumed cause
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
BufferMode input
input variable.
variable to a motion
control instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
CoordSystem input
input variable.
variable to a motion
control instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
CircMode input
input variable.
variable to a motion
control instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
Direction input vari-
input variable.
able to a motion
control instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
PathChoice input
input variable.
variable to a motion
control instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
ReferenceType
input variable.
input variable to a
motion control
instruction is out of
range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
MoveMode input
input variable.
variable to a motion
control instruction is
out of range.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
TransitionMode
input variable.
input variable to a
• _mcAborting or _mcBuffered
motion control
was specified for BufferMode
instruction is out of
and _mcTMCornerSuperim-
range.
posed was specified for Transi-
tionMode.
The value of the
• The value of the reserved input
reserved input vari-
variable Continuous changed.
able Continuous to
a motion control
instruction
changed.
The parameter
• Instruction input parameter
specified for the
exceeded the valid range of the
CombineMode
input variable.
input variable to a
motion control
instruction is out of
range.
Level
Maj
Prt
Min
Obs Info
S
S
S
S
S
S
S
S
S
S
NJ/NX-series Troubleshooting Manual (W503)
Reference
W508
W508
W508
W508
W508
W508
W508
W508
W508
W508

Advertisement